Washing machine - How to replace the temperature probe harness
Problema
How to replace the temperature probe harness
Taikoma
- Washing machine
Sprendimas

Refer always to your product’s user manual safety information before any repair or maintenance operation. https://www.electrolux.com/support/user-manuals/

WARNING! RISK OF ELECTRIC SHOCK
Before any repair or maintenance operation, deactivate the appliance and disconnect the mains plug from the socket.


WARNING! RISK OF INJURY

Always take care when moving appliances. For heavy appliances it's safest for two persons to move it. Always use safety gloves and safety footwear. Wear safety gloves at all times to protect from cuts from sharp edges.

WARNING! RISK OF EYE INJURY

Wear safety glasses if you perform maintenance or repair work involving springs.

WARNING! RISK OF PINCHING

Wear safety glovesif you perform maintenance or repair work involving belts.

WARNING! CHOKING HAZARD
Small parts not for children under 3 years. Keep all small parts and packaging out of reach of children.
Only adults should use or install the product.
Before any maintenance operation, turn off water supply to the appliance. Always empty the appliance of all the water. Any maintenance should be carried out with the appliance standing upright. Residual water could damage electronics if the appliance is placed on any of its sides.
Make sure to use the product only for its designated purpose and verify that it is a compatible part for the intended product.
Do not use or install the product if damaged.
Please note that self-repair or nonprofessional repair can have safety consequences if not done properly and might void the warranty. Possessing the necessary know-how is essential.
HOW TO REPLACE HARNESS, TEMPERATURE PROBE
1. Unscrew the two 8mm screws on the back of the washing machine lid and slide back to release.



2. Unclip the three cable holders for the wiring harness using pliers/flat blade screwdriver.

3. Use a small flat blade screwdriver to release the harness from the cable tie holder. NOTE: During reinstallation ensure the wiring harness is properly secured by the cable tie holders.

4. Carefully remove the wiring harness connectors from the temperature sensor spade. NOTE: Ensure that the connectors are properly connected during reinstallation. Be careful not to damage the connectors.

5. Carefully remove the securing tape for the wiring harness. Ensure that the wiring harness is properly wrapped in insulation tape during reinstallation.

6. Unclip the wiring harness from it’s connector to release the wiring harness.

7. Remove the wiring harness from the appliance.

8. When assembling, repeat steps in reverse order.